Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32.506
Filtrar
1.
BMC Oral Health ; 24(1): 455, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622680

RESUMEN

BACKGROUND: The aim of this study is to evaluate the biomechanical behavior of the mesial and distal off-axial extensions of implant-retained prostheses in the posterior maxilla with different prosthetic materials using finite element analysis (FEA). METHODS: Three dimensional (3D) finite element models with three implant configurations and prosthetic designs (fixed-fixed, mesial cantilever, and distal cantilever) were designed and modelled depending upon cone beam computed tomography (CBCT) images of an intact maxilla of an anonymous patient. Implant prostheses with two materials; Monolithic zirconia (Zr) and polyetherketoneketone (PEKK) were also modeled .The 3D modeling software Mimics Innovation Suite (Mimics 14.0 / 3-matic 7.01; Materialise, Leuven, Belgium) was used. All the models were imported into the FE package Marc/Mentat (ver. 2015; MSC Software, Los Angeles, Calif). Then, individual models were subjected to separate axial loads of 300 N. Von mises stress values were computed for the prostheses, implants, and bone under axial loading. RESULTS: The highest von Mises stresses in implant (111.6 MPa) and bone (100.0 MPa) were recorded in distal cantilever model with PEKK material, while the lowest values in implant (48.9 MPa) and bone (19.6 MPa) were displayed in fixed fixed model with zirconia material. The distal cantilever model with zirconia material yielded the most elevated levels of von Mises stresses within the prosthesis (105 MPa), while the least stresses in prosthesis (35.4 MPa) were recorded in fixed fixed models with PEKK material. CONCLUSIONS: In the light of this study, the combination of fixed fixed implant prosthesis without cantilever using a rigid zirconia material exhibits better biomechanical behavior and stress distribution around bone and implants. As a prosthetic material, low elastic modulus PEKK transmitted more stress to implants and surrounding bone especially with distal cantilever.


Asunto(s)
Implantes Dentales , Circonio , Humanos , Análisis de Elementos Finitos , Maxilar/cirugía , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental/métodos , Estrés Mecánico
2.
Clin Oral Investig ; 28(5): 255, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38630185

RESUMEN

OBJECTIVES: To evaluate the trueness of the digital maxillary occlusal records in comparison with the conventional records for the fabrication of complete-arch implant-supported fixed prostheses. MATERIALS AND METHODS: This randomized controlled clinical trial followed the recommendations of the CONSORT statement. Twenty participants who used a mandibular interim complete-arch fixed prosthesis and conventional complete maxillary dentures were included in the study. The participants were randomized into two types of maxillary occlusal records: conventional (COR) and digital (DOR) (TRIOS; Shape A/S). After fabricating the prostheses, the distribution and number of occlusal contact points, and the time taken to obtain the maxillary occlusal record and work model were evaluated. Descriptive analysis was used to evaluate the distribution of occlusal contact points. The Wilcoxon test was employed for assessing the number of occlusal contact points, while the Mann-Whitney U test was used for the time taken to obtain the working casts and the maxillary occlusal record and occlusal adjustment times (p < 0.05). RESULTS: There was a similarity in the jaw relation recording methods regarding the distribution of occlusal contact points. There was no difference in the number of occlusal contact points between the anterior (p = 0.439) and posterior (p = 0.227) teeth. No relationship was observed between the distribution and number of occlusal contact points (COR, p = 0.288; DOR, p = 0.183). DOR required less occlusal and clinical adjustment time, on the other hand more laboratory and total workflow time than COR (p < 0.001). CONCLUSION: The DOR may be an option for obtaining the functional space necessary for the assembly of teeth in complete-arch implant-supported fixed prostheses; however, it requires more working time. CLINICAL RELEVANCE: The digital occlusal recording method can be used to assess the interocclusal space for the virtual tooth setup of a complete-arch implant-supported fixed prosthesis.


Asunto(s)
Implantes Dentales , Humanos , Dentadura Completa , Registro de la Relación Maxilomandibular , Laboratorios , Mandíbula
3.
J Cell Mol Med ; 28(8): e18297, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38613351

RESUMEN

Autophagy is a cellular process that is evolutionarily conserved, involving the sequestration of damaged organelles and proteins into autophagic vesicles, which subsequently fuse with lysosomes for degradation. Autophagy controls the development of many diseases by influencing apoptosis, inflammation, the immune response and different cellular processes. Autophagy plays a significant role in the aetiology of disorders associated with dentistry. Autophagy controls odontogenesis. Furthermore, it is implicated in the pathophysiology of pulpitis and periapical disorders. It enhances the survival, penetration and colonization of periodontal pathogenic bacteria into the host periodontal tissues and facilitates their escape from host defences. Autophagy plays a crucial role in mitigating exaggerated inflammatory reactions within the host's system during instances of infection and inflammation. Autophagy also plays a role in the relationship between periodontal disease and systemic diseases. Autophagy promotes wound healing and may enhance implant osseointegration. This study reviews autophagy's dento-alveolar effects, focusing on its role in odontogenesis, periapical diseases, periodontal diseases and dental implant surgery, providing valuable insights for dentists on tooth development and dental applications. A thorough examination of autophagy has the potential to discover novel and efficacious treatment targets within the field of dentistry.


Asunto(s)
Implantes Dentales , Enfermedades Periodontales , Humanos , Autofagia , Odontogénesis , Inflamación
4.
BMC Oral Health ; 24(1): 443, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38605356

RESUMEN

BACKGROUND: Peri-implant disease and health are associated with microbial dental plaque. Therefore, oral hygiene plays a role in preventing and treating these diseases. This study aimed to determine the relationships among knowledge of peri-implant status, oral hygiene habits, and peri-implant disease and health. METHODS: A total of 144 implants in nonsmokers with controlled systemic disease were included in the study. Peri-implant disease and the conditions of the implants were determined with periodontal indices and radiographs based on the 2017 World Workshop on the Classification of Periodontal and Peri-implant Diseases and Conditions and The EFP S3 level clinical practice guideline. Individuals were asked 66 questions regarding demographic information, oral hygiene habits and history, and knowledge of peri-implant diseases. One-way ANOVA was used to compare the three peri-implant disease and condition categories. RESULTS: There was a significant difference between groups regarding toothpaste type (p < 0.05). Gum protection toothpaste was greater in the peri-implant health group. Patients' use of interdental products was very low; often, no products were used for implant prosthesis. There was no significant difference among the groups regarding oral hygiene product use or oral hygiene habits (p > 0.05). There was a significant difference between groups regarding frequency of visit (p < 0.05). The frequency of visits to the dentist for pain was greater for individuals with peri-implantitis. There is a significant difference between the groups' answers for the causative and initiating factors of peri-implant disease (p < 0.05). The peri-implant health group answered that microbial dental plaque is the most crucial initiating factor of peri-implant diseases, and bleeding on probing is the most critical determinant of peri-implant diseases at a higher rate than the other groups. CONCLUSIONS: Patients' oral hygiene habits and knowledge levels are almost similar according to peri-implant status. Knowledge does not reflect a patient's oral hygiene behavior. Clinicians should ensure that individuals' oral hygiene practices align with their increased awareness regarding peri-implant illnesses.


Asunto(s)
Implantes Dentales , Placa Dental , Periimplantitis , Humanos , Periimplantitis/complicaciones , Higiene Bucal , Placa Dental/prevención & control , Pastas de Dientes , Hábitos
5.
Br Dent J ; 236(7): 507, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38609594
6.
Br Dent J ; 236(7): 563, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38609626
7.
8.
Int J Oral Sci ; 16(1): 28, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38584185

RESUMEN

The use of robots to augment human capabilities and assist in work has long been an aspiration. Robotics has been developing since the 1960s when the first industrial robot was introduced. As technology has advanced, robotic-assisted surgery has shown numerous advantages, including more precision, efficiency, minimal invasiveness, and safety than is possible with conventional techniques, which are research hotspots and cutting-edge trends. This article reviewed the history of medical robot development and seminal research papers about current research progress. Taking the autonomous dental implant robotic system as an example, the advantages and prospects of medical robotic systems would be discussed which would provide a reference for future research.


Asunto(s)
Implantes Dentales , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Robótica/métodos , Predicción
9.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(2): 172-180, 2024 Apr 01.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-38597077

RESUMEN

OBJECTIVES: The effect of TiO2 nanotube morphology on the differentiation potency of senescent periodontal ligament stem cells was investigated. METHODS: Two types of titanium sheets with TiO2 nanotube morphology (20V-NT and 70V-NT) were prepared via anodic oxidation at 20 and 70 V separately, and their surface morphology was observed. Young periodontal ligament stem cells were cultivated in an osteogenic induction medium, and the most effective surface morphology in promoting osteogenic differentiation was selected. RO3306 and Nutlin-3a were used to induce the aging of young periodontal ligament stem cells, and senescent periodontal ligament stem cells were obtained. The osteogenic differentiation of senescent periodontal ligament stem cells was induced, and the effect of surface morphology on osteogenic differentiation was observed. RESULTS: Nanotube morphology was achieved on the surfaces of titanium sheets through anodic oxidation, and the diameters of the nanotubes increased with voltage. A significant difference in the effect of nanotube morphology was found among nanotubes with different diameters in the young periodontal ligament stem cells. The surface nanotube morphology of 20V-NT had a more significant effect that promoted osteogenic differentiation. Compared with a smooth titanium sheet, the surface nanotube morphology of 20V-NT increased the number of alkaline phosphatase-positive senescent periodontal ligament stem cells and promoted calcium deposition and the expression of osteogenic marker genes Runt-related transcription factor 2, osteopontin, and osteocalcin. CONCLUSIONS: A special nanotube morphology enhances the differentiation ability of senescent periodontal ligament stem cells, provides an effective method for periodontal regeneration, and further improves the performance of implants.


Asunto(s)
Implantes Dentales , Osteogénesis , Ligamento Periodontal/metabolismo , Titanio/metabolismo , Titanio/farmacología , Células Madre , Diferenciación Celular , Proliferación Celular , Células Cultivadas , Fosfatasa Alcalina/genética , Fosfatasa Alcalina/metabolismo , Fosfatasa Alcalina/farmacología
10.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(2): 207-213, 2024 Apr 01.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-38597080

RESUMEN

OBJECTIVES: To determine the optimal placement of miniscrews, this study compared adult male and female patients in terms of cortical bone density, cortical bone thickness, and available bone width in the infrazygomatic crest region. METHODS: The cone beam computed tomography imaging data of 200 patients (20-30 years old; 100 males and 100 females) were collected. The right maxillary posterior teeth in the sagittal plane were divided into six levels from proximal to distal, and three measurement sites were positioned at vertical distances of 8, 10, and 12 mm from the cementum. Cortical bone density, cortical bone thickness, and available bone width were measured in 18 measurement sites in the infrazygomatic crest and analyzed statistically. RESULTS: The highest cortical bone density, cortical bone thickness, and available bone width in the infrazygomatic crest in adult male and female patients were at the level of the interradicular space between the maxillary second premolar and maxillary first molar. The bone cortical density and thickness increased with vertical height, whereas the available bone width decreased with increasing vertical height. Differences were observed in cortical bone density, cortical bone thickness, and available bone width between adult male and female patients. CONCLUSIONS: The optimal implantation sites of the micro-implant anchorages in the infrazygomatic crest were at the level of the interradicular space between the maxillary second premolar and the maxillary first molar, and the vertical height of the optimal implantation site in males was appropriately higher than that in females.


Asunto(s)
Implantes Dentales , Métodos de Anclaje en Ortodoncia , Adulto , Humanos , Masculino , Femenino , Adulto Joven , Tomografía Computarizada de Haz Cónico/métodos , Diente Molar , Diente Premolar , Maxilar/diagnóstico por imagen , Métodos de Anclaje en Ortodoncia/métodos
11.
BMC Oral Health ; 24(1): 410, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38566034

RESUMEN

BACKGROUND: To clinically compare the effect of the conventional and the digital workflows on the passive fit of a screw retained bar splinting two inter-foraminal implants. METHODS: The current study was designed to be a parallel triple blinded randomised clinical trial. Thirty six completely edentulous patients were selected and simply randomized into two groups; conventional group (CG) and digital group (DG). The participants, investigator and outcome assessor were blinded. In the group (CG), the bar was constructed following a conventional workflow in which an open top splinted impression and a lost wax casting technology were used. However, in group (DG), a digital workflow including a digital impression and a digital bar milling technology was adopted. Passive fit of each bar was then evaluated clinically by applying the screw resistance test using the "flag" technique in the passive and non passive situations. The screw resistance test parameter was also calculated. Unpaired t-test was used for intergroup comparison. P-value < 0.05 was the statistical significance level. The study protocol was reviewed by the Research Ethics Committee in the author's university (Rec IM051811). Registration of the clinical trial was made on clinical trials.gov ID NCT05770011. An informed consent was obtained from all participants. RESULTS: Non statistically significant difference was denoted between both groups in all situations. In the passive situation, the mean ± standard deviation values were 1789.8° ± 20.7 and1786.1° ± 30.7 for the groups (CG) and (DG) respectively. In the non passive situation, they were 1572.8° ± 54.2 and 1609.2° ± 96.9. Regarding the screw resistance test parameter, they were 217° ± 55.3 and 176° ± 98.8. CONCLUSION: Conventional and digital fabrication workflows had clinically comparable effect on the passive fit of screw retained bar attachments supported by two dental implants.


Asunto(s)
Implantes Dentales , Boca Edéntula , Humanos , Flujo de Trabajo , Técnica de Impresión Dental , Tornillos Óseos , Diseño Asistido por Computadora , Prótesis Dental de Soporte Implantado/métodos , Diseño de Prótesis Dental
13.
Gen Dent ; 72(3): 34-40, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38640004

RESUMEN

The majority of problematic conditions resulting from dental implant treatment are inflammatory in character, but certain isolated occurrences of primary oral squamous cell carcinoma (OSCC) have been discovered in the area of implants. The goal of this study was to examine whether there is a link between dental implants and the development of OSCC in patients who have a history of a potentially malignant lesion (PML) or malignancy. Using the keywords "carcinoma" AND "dental implants," a search was conducted in the MEDLINE (PubMed), National Center for Biotechnology Information, and Google Scholar databases for case reports and case series in which OSCC was discovered as a primary cancer in the region of dental implants. An initial search identified 260 articles, 247 of which were excluded based on study inclusion or exclusion criteria, leaving 13 articles chosen for inclusion and a total of 30 patients who developed primary oral cancer surrounding osseointegrated titanium-based dental implants. In the studies included in the present review, 22 (73%) of 30 patients with peri-implant cancer had a history of PML or carcinoma. There is no statistical evidence of a direct association between dental implants and OSCC in patients with a history of a PML or malignant lesion. There have been some case reports of OSCC in the region of dental implants in patients with a history of a PML or malignant lesion, but further studies are needed to prove a definitive relationship.


Asunto(s)
Carcinoma de Células Escamosas , Implantes Dentales , Neoplasias de la Boca , Humanos , Implantes Dentales/efectos adversos , Carcinoma de Células Escamosas/etiología , Carcinoma de Células Escamosas/patología , Neoplasias de la Boca/etiología
14.
Gen Dent ; 72(3): 61-66, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38640008

RESUMEN

In addition to the proper selection of techniques, appropriate treatment sequencing and prioritization are prerequisites for successful periodontal and implant procedures. The aim of this study was to provide evidence-based time frames for various procedures pertaining to periodontal and implant treatment. A literature review was conducted to collect data on tissue healing; in areas in which data were lacking, the viewpoints of experienced clinicians were solicited to establish a consensus. This review reports recommended time frames for the healing processes associated with surgical crown-lengthening procedures (both functional and esthetic), fresh socket management, alveolar ridge management, soft tissue management, sinus floor augmentation, implant loading, and peri-implant defect management.


Asunto(s)
Aumento de la Cresta Alveolar , Implantes Dentales , Elevación del Piso del Seno Maxilar , Humanos , Aumento de la Cresta Alveolar/métodos , Implantación Dental Endoósea/métodos , Administración del Tiempo
15.
Gen Dent ; 72(3): 56-60, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38640007

RESUMEN

Squamous cell carcinoma (SCC) is the type of cancer that most frequently affects the oral cavity, mainly in men older than 50 years of age. Treatment for oral SCC often involves surgical excision of the affected margins, resulting in mutilation that affects the patient's quality of life. The objective of this case report is to describe the prosthetic treatment of a 56-year-old man who underwent total glossectomy, resulting in speech and swallowing difficulties. The proposed treatment was a tongue prosthesis retained by orthodontic clasps on the mandibular first molars. After maxillary and mandibular complete-arch impressions were performed and casts were prepared for prosthetic planning, an acrylic resin plate and 3 tongue prototypes were fabricated. Esthetic and functional tests were carried out, and 2 tongue models (1 for speech and 1 for eating) were selected for acrylization, finishing, and polishing. After placement of the prostheses, the patient was referred for follow-up with a speech therapist to improve his adaptation with the prostheses. The patient was satisfied with the prostheses and able to perform the functions of chewing, swallowing, and speech production, which helped in his social reintegration and improved his quality of life.


Asunto(s)
Implantes Dentales , Neoplasias de la Boca , Neoplasias de la Lengua , Masculino , Humanos , Persona de Mediana Edad , Glosectomía/métodos , Calidad de Vida , Lengua/cirugía , Lengua/patología , Neoplasias de la Lengua/cirugía , Neoplasias de la Lengua/patología
16.
Gen Dent ; 72(3): 70-73, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38640010

RESUMEN

Treatment of peri-implant diseases focuses on reducing the bacterial load and consequent infection control. The use of local antimicrobials as an adjunct to mechanical therapy may result in a better outcome. Among antimicrobials, doxycycline stands out because of its local modulation of cytokines, microbial reduction, and clinical parameters in the treatment of periodontal diseases. The objective of this case report was to describe the combined application of mechanical debridement and bioresorbable doxycycline-loaded nanospheres for the treatment of peri-implantitis in a 71-year-old man. At the 3-year evaluation, the peri-implant tissues had improved, showing decreased probing depths, an absence of bleeding on probing, and no suppuration. This case report highlights the importance of supportive therapy, which is essential for the long-term success of peri-implantitis treatment.


Asunto(s)
Antiinfecciosos , Implantes Dentales , Nanosferas , Periimplantitis , Masculino , Humanos , Anciano , Periimplantitis/tratamiento farmacológico , Periimplantitis/microbiología , Doxiciclina/uso terapéutico , Estudios de Seguimiento , Desbridamiento , Implantes Absorbibles , Antiinfecciosos/uso terapéutico , Resultado del Tratamiento
17.
J Mech Behav Biomed Mater ; 154: 106537, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38588632

RESUMEN

The Advanced System for Implant Stability Testing (ASIST) is a device currently being developed to noninvasively measure implant stability by estimating the mechanical stiffness of the bone-implant interface, which is reported as the ASIST Stability Coefficient (ASC). This study's purpose was to determine whether changes in density, bonding, and drilling technique affect the measured vibration of a dental implant, and whether they can be quantified as a change in the estimated BII stiffness. Stability was also measured using RFA, insertion torque (IT) and the pullout test. Bone-level tapered implants (4.1 mm diameter, 10 mm length) were inserted in polyurethane foam as an artificial bone substitute. Samples were prepared using different bone densities (20, 30, 40 PCF), drilling sequences, and superglue to simulate a bonded implant. Measurements were compared across groups at a significance level of 0.05. The ASC was able to indicate changes in each factor as a change in the interfacial stiffness. IT and pullout force values also showed comparable increases. Furthermore, the relative difference in ISQ values between experimental groups was considerably smaller than the ASC. While future work should be done using biological bone and in-vivo systems, the results of this in-vitro study suggest that modelling of the implant system with a vibration-based approach may provide a noninvasive method of assessing the mechanical stability of the implant.


Asunto(s)
Sustitutos de Huesos , Implantes Dentales , Vibración , Huesos , Densidad Ósea , Torque
18.
Head Face Med ; 20(1): 24, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627712

RESUMEN

OBJECTIVES: A randomized controlled clinical trial of dental implants was conducted to compare the clinical properties of a novel electrochemically deposited calcium phosphate coating to those of a common marketed surface treatment. MATERIAL AND METHODS: Forty implants of the same brand and type were placed in 20 fully edentulous participants requiring mandibular implantation. The two study groups were defined by the surface treatment of the implants. 20 implants in the control group were coated via a commercial electrochemical surface treatment that forms a mixture of brushite and hydroxyapatite, while the remaining 20 in the test group were coated with a novel electrochemical Smart Bioactive Trabecular Coating (SBTC®). A split-mouth design was employed, with each participants receiving one control implant in one mandibular side and a test implant in the other. To mitigate potential operator-handedness bias, control and test implants were randomly assigned to mandibular sides. All cases underwent digital planning, implant placement with a static surgical guide, and participants received locator-anchored full-arch dentures. The primary outcome was implant stability (measured using Osstell ISQ) assessed at insertion, loading, and then 3 months, 9 months, and 2 years post-insertion. The secondary outcome was bone level change (in millimeters) over the 2-year observation period. Oral health-related quality of life (OHRQL) was monitored using the OHIP-14 questionnaire. Complications and adverse events were recorded. RESULTS: Successful osseointegration and implant stability were achieved in all cases, allowing loading. ISQ values steadily increased throughout the observation period. While no significant differences were observed between the SBTC® and control coatings, the test group exhibited a higher ISQ gain. Bone resorption was somewhat lower in the SBTC® but not significantly so. Patients' OHRQL significantly improved after denture delivery and remained stable throughout the follow-up. No complications or adverse events were observed. CONCLUSIONS: Based on the study results, we conclude that the new surface treatment is a safe alternative to the widely used control surface, demonstrating similar osseointegrative properties and time-dependent bone level changes. Further research may explore the broader implications of these findings. TRIAL REGISTRATION: The study is registered on clinicaltrials.gov under the identifier ID: NCT06034171.


Asunto(s)
Implantes Dentales , Boca Edéntula , Humanos , Implantación Dental Endoósea/métodos , Calidad de Vida , Oseointegración , Resultado del Tratamiento , Prótesis Dental de Soporte Implantado/métodos , Diseño de Prótesis Dental
19.
Trials ; 25(1): 267, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627819

RESUMEN

BACKGROUND: Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods. METHODS/DESIGN: We will recruit 26 completely edentulous participants (any sex/gender) based on the following eligibility criteria: age ≥ 60 years, no tooth extraction in the past 12 months, two implants in the lower jaw, and need for new dentures in both jaws. Each participant will receive two denture pairs, either manufactured by 3D printing or traditionally, to be worn in a random order. A timeline of 3 months with each denture pair will be considered for outcome assessment (total: 6 months). Patient satisfaction with dentures will be measured by the McGill Denture Satisfaction Questionnaire. We will evaluate other patient-reported outcomes (including oral health-related quality of life) as well as clinician-assessed quality and cost. At the end of the trial, participants will choose which denture pair they wish to keep and interviewed about their experiences with the 3D-printed IMO. The quantitative and qualitative data will be incorporated through an explanatory mixed-methods strategy. A final quantitative assessment will happen after 12 months with the preferred IMO to assess the long-term performance and maintenance needs. DISCUSSION: This mixed-methods RCT will explore patient experiences with 3D-printed IMOs, aiming to assess the potential for altering clinical practice and dental public health policies. Our results will inform policies by showing whether 3D printing offers comparable outcomes at lower costs, facilitating greater access to oral care for the elderly. TRIAL REGISTRATION: ClinicalTrials.gov, NCT06155630, Registered on 04 December 2023. https://classic. CLINICALTRIALS: gov/ct2/show/NCT06155630.


Asunto(s)
Implantes Dentales , Arcada Edéntula , Humanos , Anciano , Persona de Mediana Edad , Prótesis de Recubrimiento , Flujo de Trabajo , Mandíbula/cirugía , Satisfacción del Paciente , Impresión Tridimensional , Prótesis Dental de Soporte Implantado , Ensayos Clínicos Controlados Aleatorios como Asunto
20.
BMC Oral Health ; 24(1): 420, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38580965

RESUMEN

BACKGROUND: Interstitial brachytherapy is a form of intensive local irradiation that facilitates the effective protection of surrounding structures and the preservation of organ functions, resulting in a favourable therapeutic response. As surgical robots can perform needle placement with a high level of accuracy, our team developed a fully automatic radioactive seed placement robot, and this study aimed to evaluate the accuracy and feasibility of fully automatic radioactive seed placement for the treatment of tumours in the skull base. METHODS: A fully automatic radioactive seed placement robot was established, and 4 phantoms of skull base tumours were built for experimental validation. All the phantoms were subjected to computed tomography (CT) scans. Then, the CT data were imported into the Remebot software to design the preoperative seed placement plan. After the phantoms were fixed in place, navigation registration of the Remebot was carried out, and the automatic seed placement device was controlled to complete the needle insertion and particle placement operations. After all of the seeds were implanted in the 4 phantoms, postoperative image scanning was performed, and the results were verified via image fusion. RESULTS: A total of 120 seeds were implanted in 4 phantoms. The average error of seed placement was (2.51 ± 1.44) mm. CONCLUSION: This study presents an innovative, fully automated radioactive particle implantation system utilizing the Remebot device, which can successfully complete automated localization, needle insertion, and radioactive particle implantation procedures for skull base tumours. The phantom experiments showed the robotic system to be reliable, stable, efficient and safe. However, further research on the needle-soft tissue interaction and deformation mechanism of needle puncture is still needed.


Asunto(s)
Implantes Dentales , Robótica , Neoplasias de la Base del Cráneo , Humanos , Neoplasias de la Base del Cráneo/diagnóstico por imagen , Neoplasias de la Base del Cráneo/radioterapia , Neoplasias de la Base del Cráneo/cirugía , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...